Braemar Error Code 45

Fault Code 45: Combustion air pressure too low during run.

Need help with your Braemar System?

    Please select accurately so we can provide you with the best service providers in your immediate vicinity.



    Call us at: 1300665137
    Or send us an email at: [email protected]

     

    Braemar Fault Code 45

    Fault: Combustion air pressure too low during run.

    Potential Cause (Technical Use Only: Potential remedy):

    • Swarf obstruction combustion fan pressure tapping.  Check both ends of pressure tapping – clear obstruction or replace pressure tapping. 
    • Condensate intermittently blocking combustion fan suction hose.  Clear blockage.  Check flue condensate drain fitted correctly (condensing models only). 
    • Flue partly blocked, making system more susceptible to wind effects.  Check and clear blockage, check flue cowl is not pushed on too far. 
    • Severe wind on flue terminal, or poor flue terminal location (eg, too close to roof).  Check flue terminal location – re‐ locate if necessary.

    For Braemar Ecostar TQ, TQM, TQS, TQMD, BMQ Gas Ducted Heaters and Braemar Supernova TQS Gas Ducted Heaters.