Fault Code 12: PS high closed at start.  Condensate blocking combustion fan suction hose. Faulty pressure switch, contacts stuck closed.

Need help with your Braemar System?

    Please select accurately so we can provide you with the best service providers in your immediate vicinity.



    Call us at: 1300665137
    Or send us an email at: [email protected]

     

    Fault Code 12

    Fault: PS high closed at start.  Condensate blocking combustion fan suction hose. Faulty pressure switch, contacts stuck closed.

    Potential Cause (Technical Use Only: Potential remedy):

    • Clear blockage.  Check flue condensate drain fitted correctly (condensing models only).
    • Replace pressure switch if required

     


    For Braemar Ecostar TQ, TQM, TQS, TQMD, BMQ Gas Ducted Heaters and Braemar Supernova TQS Gas Ducted Heaters.