Braemar Error Code 22

Fault Code 22: Supply voltage out of range.

Need help with your Braemar System?

    Please select accurately so we can provide you with the best service providers in your immediate vicinity.



    Call us at: 1300665137
    Or send us an email at: [email protected]

     

    Braemar Fault Code 22

    Fault: Supply voltage out of range.

    Potential Cause (Technical Use Only: Potential remedy):

    • Partial power supply interruption – “brown out”.  Check electricity supply history with customer. 
    • Reduced electricity supply.  Check heater supply voltage with heater and all other electrical appliances running. Arrange to have supply upgraded if required. 
    • Faulty heater transformer.  Check transformer with heater operating ‐ should have approx. 24Vac out with 240Vac in

    For Braemar Ecostar TQ, TQM, TQS, TQMD, BMQ Gas Ducted Heaters and Braemar Supernova TQS Gas Ducted Heaters.