Braemar Error Code 9

Fault Code 9: The thermistor temperature is above 60oC during a start cycle – most likely due to a start cycle after a power blackout

Need help with your Braemar System?

    Please select accurately so we can provide you with the best service providers in your immediate vicinity.



    Call us at: 1300665137
    Or send us an email at: [email protected]

     

    Braemar Fault Code 09

    Fault: The thermistor temperature is above 60oC during a start cycle – most likely due to a start cycle after a power blackout

    Potential Cause (Technical Use Only: Potential remedy):

    If there is no obvious reason for the thermistor temperature being > 60oC when starting, such as a power supply interruption, check the following:

    • Thermistor connection to ICS – rectify if required.
    • Thermistor and thermistor cable condition – replace if damaged.
    • Thermistor location – re‐locate to 3m from heater outlet if required

     


    For Braemar Ecostar TQ, TQM, TQS, TQMD, BMQ Gas Ducted Heaters and Braemar Supernova TQS Gas Ducted Heaters.