Brivis Error Code 50

Error Code h01 50: Ignition Lockout. The maximum number of ignition attempts has been exceeded within a heat cycle.

Need help with your Brivis System?

    Please select accurately so we can provide you with the best service providers in your immediate vicinity.



    Call us at: 1300665137
    Or send us an email at: [email protected]

     

    Brivis Fault Code 50

    Brivis Error Code 50 Ignition Lockout: The maximum number of ignition attempts has been exceeded within a heat cycle.

    For Heater Repair Tech Only

    Reason: This error code indicates the unit has locked out after 5 ignition attempts without the flame being recognised by the flame sensor. Service Check List: • Refer to Check List for Error Code 46: IGR_NOFLM.
    Corrective actions:
    • Check the gas supply is turned on at the meter, and at the appliance gas cock.
    • Check if other gas appliances are operating such as Gas Cooker and Hot Water Service (if installed).
    • Check the gas cylinders have gas, and the cylinder valve is open (LPG only).
    • Check that there is gas supply to the home. Contact the gas provider to confirm this. There may be works in the area or a problem with the supply.
    • The heater may require a general service.