Brivis Error Code 60

Error Code h01 60: Motor Open Circuit. No zero cross detect signal has been sensed for at least the zero cross detect failure time indicating that a motor open circuit fault exists.

Need help with your Brivis System?

    Please select accurately so we can provide you with the best service providers in your immediate vicinity.



    Call us at: 1300665137
    Or send us an email at: [email protected]

     

    Brivis Fault Code 60

    Brivis Error Code 60 Motor Open Circuit: No zero cross detect signal has been sensed for at least the zero cross detect failure time indicating that a motor open circuit fault exists.

    For Heater Repair Tech Only

    Reason: This error code indicates the main fan motor is “open circuit”. Service Check List: • Check the wiring to the motor, and the plug connections are connected satisfactorily. • Check for signs of damage to the motor loom or motor extension loom • Check that the motor winding resistances are within specifications as shown below. (Note: The resistances specified are when the motors winding temperatures are at 20°C, and will vary if the motors temperature is hotter or cooler). Fasco 315W – 80855BNVA-A20 Fasco 650W – 80855BPVA-A12 Start Winding resistance @ 20°C 37.5 – 43.2 Ω 10.0 – 11.5 Ω Main Winding resistance @ 20°C 9.8 – 11.3 Ω 6.2 – 7.1 Ω • Check if the motor casing is HOT, indicating the motor’s thermal over temperature switch may be tripped. If the motor is hot: • Check motor bearings for wear and stiffness. • Check the capacitor is the correct size and/or faulty. • Check the fan impellor is not damaged, jammed, blocked or obstructed. • Check the incoming power supply voltage.

    SKU: 334 Category: Tag: