Error Code h01 61; Primary Valve Stuck Off. On energising the primary valve control relay its contact is not detected as closed within the primary valve control relay contact closed verification time indicating that it is stuck off.
Brivis Error Code 61 Primary Valve Stuck Off: On energising the primary valve control relay its contact is not detected as closed within the primary valve control relay contact closed verification time indicating that it is stuck off.
For Heater Repair Tech Only
Reason: This error code indicates on energising the primary valve control relay its contact is not detected as closed within the primary valve control relay contact closed and indicating that it is “stuck off”. Service Check List: If Error 61 has occurred in the past on this heater then replace the NG-2 Module For a first time Error 61 reset NG-2 Module then retry heater operation. If NG-2 cannot be reset or if Error 61 reoccurs then replace NG-2 module and retest.