Error Code h01 65: Motor Lockout. While the fan limp fault is registered and a motor open circuit occurs or an overheat cool down is initiated the motor lockout fault is flagged.

Need help with your Brivis System?

    Please select accurately so we can provide you with the best service providers in your immediate vicinity.



    Call us at: 1300665137
    Or send us an email at: [email protected]

     

    Brivis Fault Code 65

    Brivis Error Code 65 Motor Lockout: While the fan limp fault is registered and a motor open circuit occurs or an overheat cool down is initiated the motor lockout fault is flagged.

    For Heater Repair Tech Only

    Reason: The unit is locked out due to fan motor open circuit (Error 60), and the fan motor speed sensor signal has not been received by the NG-2 (Error 30). OR The unit was operating in FAN_LIMP mode (Error 30), and an over temperature condition has occurred (Error 40, 41, or 42). Service Check List: Refer to Check Lists for Error Code 30, 40, 41, 42 or 60, whichever has occurred.