Error Code h01 70: Remote Microcontroller Shutdown Fail. This fault indicates that the remote microcontroller did not shutdown the heating cycle within the heating cycle shutdown time.

Need help with your Brivis System?

    Please select accurately so we can provide you with the best service providers in your immediate vicinity.



    Call us at: 1300665137
    Or send us an email at: [email protected]

     

    Brivis Fault Code 70

    Brivis Error Code 70 Remote Microcontroller Shutdown Fail: This fault indicates that the remote microcontroller did not shutdown the heating cycle within the heating cycle shutdown time.

    For Heater Repair Tech Only

    Reason: This fault indicates that the secondary microcontroller did not shutdown the heating cycle within the heating cycle maximum shutdown delay time (tsdndelay=2.5s) allowed in response to a fault condition detected by the primary microcontroller (See Section 8-4.3.1, 8-5.4.1, 8-5.5.1). Service Check List: If error 70 has occurred in the past on this heater then replace the NG-2 Module For a first time Error 70 reset NG-2 Module then retry heater operation.