Braemar Error Code 14

Fault Code 14: PS high opened during run.

Need help with your Braemar System?

    Please select accurately so we can provide you with the best service providers in your immediate vicinity.



    Call us at: 1300665137
    Or send us an email at: [email protected]

     

    Fault Code 14

    Fault: PS high opened during run.

    Potential Cause (Technical Use Only: Potential remedy):

    • Swarf obstruction combustion fan pressure tapping.  Check both ends of pressure tapping – clear obstruction or replace pressure tapping. 
    • Condensate intermittently blocking combustion fan suction hose.  Clear blockage.  Check flue condensate drain fitted correctly (condensing models only). 
    • Flue partly blocked, making system more susceptible to wind effects.  Check and clear blockage, check flue cowl is not pushed on too far. 
    • Severe wind on flue terminal, or poor flue terminal location (eg, too close to roof).  Check flue terminal location – re‐ locate if necessary.

     


    For Braemar Ecostar TQ, TQM, TQS, TQMD, BMQ Gas Ducted Heaters and Braemar Supernova TQS Gas Ducted Heaters.