Braemar Error Code 24

Fault Code 24: Room fan running backwards.

Need help with your Braemar System?

    Please select accurately so we can provide you with the best service providers in your immediate vicinity.



    Call us at: 1300665137
    Or send us an email at: [email protected]

     

    Braemar Fault Code 24

    Fault: Room fan running backwards.

    Potential Cause (Technical Use Only: Potential remedy):

    • Room fan capacitor disconnected at capacitor or at ICS capacitor terminals.  Reconnect room fan capacitor wiring in accordance with wiring diagram. 
    • Room fan capacitor failed.  Check and replace room fan capacitor. 
    • Faulty room fan motor.  Check direction of rotation – replace room fan motor if required.

    For Braemar Ecostar TQ, TQM, TQS, TQMD, BMQ Gas Ducted Heaters and Braemar Supernova TQS Gas Ducted Heaters.